{ config, lib, pkgs, ... }:
|
|
|
|
|
|
|
|
# TODO: This is not secure, have a look at the file docs/security.txt inside
|
|
|
|
# the project sources.
|
|
|
|
with lib;
|
|
|
|
|
|
|
|
let
|
|
|
|
cfg = config.power.ups;
|
|
|
|
in
|
|
|
|
|
|
|
|
let
|
|
|
|
upsOptions = {name, config, ...}:
|
|
|
|
{
|
|
|
|
options = {
|
2022-12-28 21:21:41 +00:00
|
|
|
# This can be inferred from the UPS model by looking at
|
2020-04-24 23:36:52 +00:00
|
|
|
# /nix/store/nut/share/driver.list
|
|
|
|
driver = mkOption {
|
|
|
|
type = types.str;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
Specify the program to run to talk to this UPS. apcsmart,
|
|
|
|
bestups, and sec are some examples.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
port = mkOption {
|
|
|
|
type = types.str;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
The serial port to which your UPS is connected. /dev/ttyS0 is
|
|
|
|
usually the first port on Linux boxes, for example.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
shutdownOrder = mkOption {
|
|
|
|
default = 0;
|
|
|
|
type = types.int;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
When you have multiple UPSes on your system, you usually need to
|
|
|
|
turn them off in a certain order. upsdrvctl shuts down all the
|
|
|
|
0s, then the 1s, 2s, and so on. To exclude a UPS from the
|
|
|
|
shutdown sequence, set this to -1.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
maxStartDelay = mkOption {
|
|
|
|
default = null;
|
|
|
|
type = types.uniq (types.nullOr types.int);
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
This can be set as a global variable above your first UPS
|
|
|
|
definition and it can also be set in a UPS section. This value
|
|
|
|
controls how long upsdrvctl will wait for the driver to finish
|
|
|
|
starting. This keeps your system from getting stuck due to a
|
|
|
|
broken driver or UPS.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
description = mkOption {
|
|
|
|
default = "";
|
|
|
|
type = types.str;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
Description of the UPS.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
directives = mkOption {
|
|
|
|
default = [];
|
|
|
|
type = types.listOf types.str;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
List of configuration directives for this UPS.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
summary = mkOption {
|
|
|
|
default = "";
|
|
|
|
type = types.lines;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
Lines which would be added inside ups.conf for handling this UPS.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
};
|
|
|
|
|
|
|
|
config = {
|
|
|
|
directives = mkOrder 10 ([
|
|
|
|
"driver = ${config.driver}"
|
|
|
|
"port = ${config.port}"
|
|
|
|
''desc = "${config.description}"''
|
|
|
|
"sdorder = ${toString config.shutdownOrder}"
|
|
|
|
] ++ (optional (config.maxStartDelay != null)
|
|
|
|
"maxstartdelay = ${toString config.maxStartDelay}")
|
|
|
|
);
|
|
|
|
|
|
|
|
summary =
|
|
|
|
concatStringsSep "\n "
|
|
|
|
(["[${name}]"] ++ config.directives);
|
|
|
|
};
|
|
|
|
};
|
|
|
|
|
|
|
|
in
|
|
|
|
|
|
|
|
|
|
|
|
{
|
|
|
|
options = {
|
|
|
|
# powerManagement.powerDownCommands
|
|
|
|
|
|
|
|
power.ups = {
|
|
|
|
enable = mkOption {
|
|
|
|
default = false;
|
|
|
|
type = with types; bool;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
Enables support for Power Devices, such as Uninterruptible Power
|
|
|
|
Supplies, Power Distribution Units and Solar Controllers.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
# This option is not used yet.
|
|
|
|
mode = mkOption {
|
|
|
|
default = "standalone";
|
|
|
|
type = types.str;
|
2022-09-09 14:08:57 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
The MODE determines which part of the NUT is to be started, and
|
|
|
|
which configuration files must be modified.
|
|
|
|
|
|
|
|
The values of MODE can be:
|
|
|
|
|
|
|
|
- none: NUT is not configured, or use the Integrated Power
|
|
|
|
Management, or use some external system to startup NUT
|
|
|
|
components. So nothing is to be started.
|
|
|
|
|
|
|
|
- standalone: This mode address a local only configuration, with 1
|
|
|
|
UPS protecting the local system. This implies to start the 3 NUT
|
|
|
|
layers (driver, upsd and upsmon) and the matching configuration
|
|
|
|
files. This mode can also address UPS redundancy.
|
|
|
|
|
|
|
|
- netserver: same as for the standalone configuration, but also
|
|
|
|
need some more ACLs and possibly a specific LISTEN directive in
|
|
|
|
upsd.conf. Since this MODE is opened to the network, a special
|
|
|
|
care should be applied to security concerns.
|
|
|
|
|
|
|
|
- netclient: this mode only requires upsmon.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
schedulerRules = mkOption {
|
|
|
|
example = "/etc/nixos/upssched.conf";
|
|
|
|
type = types.str;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
File which contains the rules to handle UPS events.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
|
|
|
|
maxStartDelay = mkOption {
|
|
|
|
default = 45;
|
|
|
|
type = types.int;
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
This can be set as a global variable above your first UPS
|
|
|
|
definition and it can also be set in a UPS section. This value
|
|
|
|
controls how long upsdrvctl will wait for the driver to finish
|
|
|
|
starting. This keeps your system from getting stuck due to a
|
|
|
|
broken driver or UPS.
|
|
|
|
'';
|
|
|
|
};
|
|
|
|
|
|
|
|
ups = mkOption {
|
|
|
|
default = {};
|
|
|
|
# see nut/etc/ups.conf.sample
|
2022-08-12 12:06:08 +00:00
|
|
|
description = lib.mdDoc ''
|
2020-04-24 23:36:52 +00:00
|
|
|
This is where you configure all the UPSes that this system will be
|
|
|
|
monitoring directly. These are usually attached to serial ports,
|
|
|
|
but USB devices are also supported.
|
|
|
|
'';
|
|
|
|
type = with types; attrsOf (submodule upsOptions);
|
|
|
|
};
|
|
|
|
|
|
|
|
};
|
|
|
|
};
|
|
|
|
|
|
|
|
config = mkIf cfg.enable {
|
|
|
|
|
|
|
|
environment.systemPackages = [ pkgs.nut ];
|
|
|
|
|
|
|
|
systemd.services.upsmon = {
|
|
|
|
description = "Uninterruptible Power Supplies (Monitor)";
|
|
|
|
after = [ "network.target" ];
|
|
|
|
wantedBy = [ "multi-user.target" ];
|
|
|
|
serviceConfig.Type = "forking";
|
|
|
|
script = "${pkgs.nut}/sbin/upsmon";
|
|
|
|
environment.NUT_CONFPATH = "/etc/nut/";
|
|
|
|
environment.NUT_STATEPATH = "/var/lib/nut/";
|
|
|
|
};
|
|
|
|
|
|
|
|
systemd.services.upsd = {
|
|
|
|
description = "Uninterruptible Power Supplies (Daemon)";
|
|
|
|
after = [ "network.target" "upsmon.service" ];
|
|
|
|
wantedBy = [ "multi-user.target" ];
|
|
|
|
serviceConfig.Type = "forking";
|
|
|
|
# TODO: replace 'root' by another username.
|
|
|
|
script = "${pkgs.nut}/sbin/upsd -u root";
|
|
|
|
environment.NUT_CONFPATH = "/etc/nut/";
|
|
|
|
environment.NUT_STATEPATH = "/var/lib/nut/";
|
|
|
|
};
|
|
|
|
|
|
|
|
systemd.services.upsdrv = {
|
|
|
|
description = "Uninterruptible Power Supplies (Register all UPS)";
|
|
|
|
after = [ "upsd.service" ];
|
|
|
|
wantedBy = [ "multi-user.target" ];
|
|
|
|
# TODO: replace 'root' by another username.
|
2021-02-05 17:12:51 +00:00
|
|
|
script = "${pkgs.nut}/bin/upsdrvctl -u root start";
|
2020-04-24 23:36:52 +00:00
|
|
|
serviceConfig = {
|
|
|
|
Type = "oneshot";
|
|
|
|
RemainAfterExit = true;
|
|
|
|
};
|
|
|
|
environment.NUT_CONFPATH = "/etc/nut/";
|
|
|
|
environment.NUT_STATEPATH = "/var/lib/nut/";
|
|
|
|
};
|
|
|
|
|
|
|
|
environment.etc = {
|
|
|
|
"nut/nut.conf".source = pkgs.writeText "nut.conf"
|
|
|
|
''
|
|
|
|
MODE = ${cfg.mode}
|
|
|
|
'';
|
|
|
|
"nut/ups.conf".source = pkgs.writeText "ups.conf"
|
|
|
|
''
|
|
|
|
maxstartdelay = ${toString cfg.maxStartDelay}
|
|
|
|
|
|
|
|
${flip concatStringsSep (forEach (attrValues cfg.ups) (ups: ups.summary)) "
|
|
|
|
|
|
|
|
"}
|
|
|
|
'';
|
|
|
|
"nut/upssched.conf".source = cfg.schedulerRules;
|
2022-12-28 21:21:41 +00:00
|
|
|
# These file are containing private information and thus should not
|
2020-04-24 23:36:52 +00:00
|
|
|
# be stored inside the Nix store.
|
|
|
|
/*
|
|
|
|
"nut/upsd.conf".source = "";
|
|
|
|
"nut/upsd.users".source = "";
|
|
|
|
"nut/upsmon.conf".source = "";
|
|
|
|
*/
|
|
|
|
};
|
|
|
|
|
|
|
|
power.ups.schedulerRules = mkDefault "${pkgs.nut}/etc/upssched.conf.sample";
|
|
|
|
|
|
|
|
system.activationScripts.upsSetup = stringAfter [ "users" "groups" ]
|
|
|
|
''
|
|
|
|
# Used to store pid files of drivers.
|
|
|
|
mkdir -p /var/state/ups
|
|
|
|
'';
|
|
|
|
|
|
|
|
|
|
|
|
/*
|
|
|
|
users.users.nut =
|
|
|
|
{ uid = 84;
|
|
|
|
home = "/var/lib/nut";
|
|
|
|
createHome = true;
|
|
|
|
group = "nut";
|
|
|
|
description = "UPnP A/V Media Server user";
|
|
|
|
};
|
|
|
|
|
|
|
|
users.groups."nut" =
|
|
|
|
{ gid = 84; };
|
|
|
|
*/
|
|
|
|
|
|
|
|
};
|
|
|
|
}
|